Model Characteristics
Formulation Characteristics
Boling Test
Water source: Deionized water
Temperature: 85°C
Time: 15 min
Results: No air bubbles generated
Aluminum Paste Pulling Test
1. Tempered glass: 20 cm × 20 cm
2. EVA: First
3. TPT: Hafron/0.3 mm
4. Packaging Temperature: 140°C
5. Pulling Direction: 180°
6. Result: 30N - 40 N
Specification
Techinical Parameters |
Technical Standards |
Testing Equipment |
Aluminum Content |
70% ~80% |
TGA Brookfield |
Viscosity |
25000~35000mPa·s |
CAP2000+Cone-and-plate viscometer
|
Fitness |
≤25um |
QXD-50 finess dispersion meter detection
|
Drying Thickness |
35±5um |
Electronic micrometer diameter measurement |
Sintered Thickness |
25±5um |
|
Resistance |
≤60mΩ/□ |
4.5-bit digital multimeter |